<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "https://jats.nlm.nih.gov/nlm-dtd/publishing/3.0/journalpublishing3.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" article-type="research-article" dtd-version="3.0" xml:lang="en">
<front>
<journal-meta>
<journal-id journal-id-type="publisher">ISPRS-Annals</journal-id>
<journal-title-group>
<journal-title>ISPRS Annals of the Photogrammetry, Remote Sensing and Spatial Information Sciences</journal-title>
<abbrev-journal-title abbrev-type="publisher">ISPRS-Annals</abbrev-journal-title>
<abbrev-journal-title abbrev-type="nlm-ta">ISPRS Ann. Photogramm. Remote Sens. Spatial Inf. Sci.</abbrev-journal-title>
</journal-title-group>
<issn pub-type="epub">2194-9050</issn>
<publisher><publisher-name>Copernicus Publications</publisher-name>
<publisher-loc>Göttingen, Germany</publisher-loc>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.5194/isprsannals-II-5-W2-85-2013</article-id>
<title-group>
<article-title>Calibration of a multi-beam Laser System by using a TLS-generated Reference</article-title>
</title-group>
<contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Gordon</surname>
<given-names>M.</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
</contrib>
<contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Meidow</surname>
<given-names>J.</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
</contrib>
</contrib-group><aff id="aff1">
<label>1</label>
<addr-line>Fraunhofer Institute of Optronics, System Technologies and Image Exploitation IOSB Ettlingen, Germany</addr-line>
</aff>
<pub-date pub-type="epub">
<day>16</day>
<month>10</month>
<year>2013</year>
</pub-date>
<volume>II-5/W2</volume>
<fpage>85</fpage>
<lpage>90</lpage>
<permissions>
<copyright-statement>Copyright: &#x000a9; 2013 M. Gordon</copyright-statement>
<copyright-year>2013</copyright-year>
<license license-type="open-access">
<license-p>This work is licensed under the Creative Commons Attribution 3.0 Unported License. To view a copy of this licence, visit <ext-link ext-link-type="uri"  xlink:href="https://creativecommons.org/licenses/by/3.0/">https://creativecommons.org/licenses/by/3.0/</ext-link></license-p>
</license>
</permissions>
<self-uri xlink:href="https://isprs-annals.copernicus.org/articles/II-5-W2/85/2013/isprs-annals-II-5-W2-85-2013.html">This article is available from https://isprs-annals.copernicus.org/articles/II-5-W2/85/2013/isprs-annals-II-5-W2-85-2013.html</self-uri>
<self-uri xlink:href="https://isprs-annals.copernicus.org/articles/II-5-W2/85/2013/isprs-annals-II-5-W2-85-2013.pdf">The full text article is available as a PDF file from https://isprs-annals.copernicus.org/articles/II-5-W2/85/2013/isprs-annals-II-5-W2-85-2013.pdf</self-uri>
<abstract>
<p>Rotating multi-beam LIDARs mounted on moving platforms have become very successful for many applications such as autonomous
navigation, obstacle avoidance or mobile mapping. To obtain accurate point coordinates, a precise calibration of such a LIDAR system
is required. For the determination of the corresponding parameters we propose a calibration scheme which exploits the information of
3D reference point clouds captured by a terrestrial laser scanning (TLS) device. It is assumed that the accuracy of this point clouds is
considerably higher than that from the multi-beam LIDAR and that the data represent faces of man-made objects at different distances.
After extracting planes in the reference data sets, the point-plane-incidences of the measured points and the reference planes are used to
formulate the implicit constraints. We inspect the Velodyne HDL-64E S2 system as the best-known representative for this kind of sensor
system. The usability and feasibility of the calibration procedure is demonstrated with real data sets representing building faces (walls,
roof planes and ground). Beside the improvement of the point accuracy by considering the calibration results, we test the significance
of the parameters related to the sensor model and consider the uncertainty of measurements w.r.t. the measured distances. The Velodyne
returns two kinds of measurements &amp;ndash; distances and encoder angles. To account for this, we perform a variance component estimation
to obtain realistic standard deviations for the observations.</p>
</abstract>
<counts><page-count count="6"/></counts>
</article-meta>
</front>
<body/>
<back>
</back>
</article>